Ingersoll Rand | <img src="/_images/aro_icon.gif" />Diaphragm Failure Detection Kit
air compressors, tools, ARO, diaphragm pumps, impact wrench, air compressor, compressed air, blowers, lifting and material handling, engine startingIngersoll Rand
67237_on_PD15S-X.png

Diaphragm Failure Detection Kit

By detecting diaphragm pump failure and resulting material leakage a DFD kit helps eliminate costly production downtime

Features

  • Cost-effective way to get your pumps wired for preventive maintenance

 

How ARO Diaphragm Failure Detection (DFD) Works

  • A refractive infrared light sensor installed into the air side of the diaphragm housing sends and receives a continuous optic signal. If diaphragm failure occurs and fluid enters the air side, the sensor's beam is absorbed and an output signal is sent indicating failure.

 

When and Where to Use ARO DFD

  • When pumping aggressive or hazardous materials that could pose a threat to the work environment
  • In remote locations where constant monitoring is critical
  • When pumping expensive materials
  • Where OSHA or EPA standards and codes require monitoring

 

Models

  • 67237
    1", 1½", 2" & 3" Metallic EXP Pumps
  • 67236-1
    For 1-1/2” Metallic Diaphragm Pumps with Cast Iron or Stainless Steel center bodies
  • 67236-2
    For 2” and 3” Metallic Diaphragm Pumps with Cast Iron or Stainless Steel center bodies