Turbine Motor Air Starter Selection Guide - Ingersoll Rand Air Starters


For more information, call 800-483-4981




Air Starter Selection Guide

 

Lubrication Free Selection Guide (Turbine Motor)

 

For Diesel Engine Displacement (liters) Series Gear Ratio Extended Starting Capability (>10 sec.) Max Power (HP) Max Pressure (psig) Air Consumption at Max HP – SCFM (L/s) Engagement Type** Inlet Size (NPT) Exhaust Size (NPT) Gas Sealed
8 to 27 150TMG F Yes 28 150 710 (335) Inertia 1 1 ⁄ 4 " 2" Yes
8 to 27 150TMP F Yes 28 150 710 (335) Pre-Engaged 1 1 ⁄ 4 " 2" Yes
8 to 27 150TLP F Yes 28 90 780 (368) Pre-Engaged 1 1 ⁄ 4 " 2" Yes
5 to 100 ST599 F Yes 44 150 1240 (585) Pre-Engaged 1 1 ⁄ 4 " 2" Yes
5 to 100 ST544 F Yes 28 150 710 (335) Pre-Engaged 1 1 ⁄ 4 " 2" Yes
16 to 80 ST650 B Yes 66 150 1450 (684) Pre-Engaged 1 1 ⁄ 4 " 5" V-Band Flange No
16 to 80 ST699 B Yes 67 90 1700 (802) Pre-Engaged 1 1 ⁄ 2 " 5" V-Band Flange No
16 to 130 ST750 B No 55 150 1300 (614) Inertia Pre-engaged 1 1 ⁄ 2 " 4" * Yes
16 to 130 ST799 B No 66 90 1700 (802) Inertia/Pre-engaged 1 1 ⁄ 2 " 4" * Yes
80 to 200 ST750 C No 55 150 1300 (614) Pre-Engaged 1 1 ⁄ 2 " 4" * Yes
80 to 200 ST799 C No 66 90 1700 (802) Pre-Engaged 1 1 ⁄ 2 " 4" * Yes
160 to 320 ST750 D No 55 150 1300 (614) Pre-Engaged 1 1 ⁄ 2 " 4" * Yes
160 to 320 ST799 D No 66 90 1700 (802) Pre-Engaged 1 1 ⁄ 2 " 4" * Yes
16 to 130 ST950 B Yes 55 150 1300 (614) Inertia/Pre-engaged 1 1 ⁄ 2 " 4" * Yes
16 to 130 ST999 B Yes 66 90 1700 (802) Inertia/Pre-engaged 1 1 ⁄ 2 " 4" * Yes
80 to 200 ST950 C Yes 55 150 1300 (614) Pre-Engaged 1 1 ⁄ 2 " 4" * Yes
80 to 200 ST999 C Yes 66 90 1700 (802) Pre-Engaged 1 1 ⁄ 2 " 4" * Yes
160 to 320 ST950 D Yes 55 150 1300 (614) Pre-Engaged 1 1 ⁄ 2 " 4" * Yes
160 to 320 ST999 D Yes 66 90 1700 (802) Pre-Engaged 1 1 ⁄ 2 " 4" * Yes
Gas Turbine Engines TS700/TS900 D Yes 130 225 2200 (1038) Permanently Engaged 1 1 ⁄ 2 " 4" * Yes

© 2016 Ingersoll Rand. All rights reserved.